Installaon & Operaon Manual
Vercal Pivot Gate (VPG) System
VPG Operator-24 (LM)
Before aempng to install, operate or
maintain the operator, you MUST read and
fully understand this manual and follow all
safety instrucons.
This product is to be installed and serviced
by a trained Gate Systems Technician only.
Contact AutoGate for a local professional in
your area.
1.800.944.4283 AutoGate Technical Support MAY 2017
2
Safety & Helpful Informaon
AutoGate and the industry has endorsed three voluntary safety standards related to automatically operated
gate systems. In the United States, UL 325 addresses the manufacturing and installation of gate openers
and in Canada the standard is CSA 22.2 no. 247-14. ASTM F2200 addresses the design and construction
of gates for vehicular traffic that are to be automated.
UL 325: Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems. For obtaining a
copy of this standard call Underwriters Laboratory at 1-888-853-3503 or order online at www.comm-
2000.com
CAN/CSA 22.2 no. 247-14: Standard for Operators and systems of Doors, Gates, Draperies and Louvres.
For obtaining a copy of this standard call CSA at 1-800-463-6727, email at [email protected]rg, or order
online at www.http://shop.csa.ca/
ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For obtaining a copy of
this standard contact ASTM at 1-877-909-2786, email at se[email protected]g or order online at
www.ASTM.org/.
Automatic vehicular gate operating systems provide convenience and security to the end user. A gate
operator is capable of producing high levels of force to move and or reverse gates. If a system is not
properly specified, installed, used, and maintained, serious injuries or death can result to someone in the
vicinity of a moving gate. Some situations that can lead to a possibility of serious injuries or death include:
absence of separate pedestrian access (automatic gates are for vehicular traffic only)
reaching through a gate to operate the system
attempting to climb under, over, or through a gate or the area covered by the travel of the gate
children playing on, or in the vicinity of, the gate
Improperly installed or physical failure of gate supporting hardware, which may allow a gate to “over
travel” or fall down or fall from its prescribed mounting position
unsafe gate designs and/or an absence of required entrapment protection devices
unsafe installations in which access control devices or pedestrian access areas have been located
within reach of or contacted by any part at any time by the moving gate
modifying a manufacturers design or components and failing to follow instructions
untrained individuals attempting to adjust, repair, or perform maintenance on a gate system
General Requirements from these standards (include, but are not limited to the following;)
1. Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 1/2” (0.50
in. /12.7 mm) other than the exceptions listed in ASTM F2200.
2. The minimum height for barbed tape shall not be less than eight foot (8’) (2.44 m) above grade.
3. The minimum height for barbed wire shall not be less than six foot (6’) (1.83 m) above grade.
4. Protrusions shall not be permitted on any gate. Refer to ASTM F2200 for exceptions
1.800.944.4283 AutoGate Technical Support MAY 2017
3
General Requirements from these standards (continued)
5. Gates shall be designed, constructed and installed such that their movement shall not be initiated by
gravity when an automatic operator is disconnected from it’s supporting or drive system hardware. A
vehicular vertical pivot gate shall be restrained from movement along the arc of its path of travel.
6. The following provisions shall apply to Class I, Class II, and Class III vehicular vertical pivot gates:
All areas of the moving gate panel from the bottom of the gate to the top of the gate or a minimum of 72 in.
(1.83 m) above grade, whichever is less, that pass by a fixed stationary object, and in the area of the
adjacent fence that the gate covers during the travel of the gate, shall be designed, guarded or screened to
prevent a 2 1⁄4 in. (57 mm) diameter sphere from passing through such areas. A gap, measured in the
horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway (such as a
gate support post) and the gate frame when the gate is in either the fully open position or the fully closed
position on vertical pivot installations, shall not exceed four (4) inches (102 mm). Exception: All other fixed
stationary objects greater than 16 inches (406 mm) from the gate frame shall not be required to comply with
this section. Horizontal and vertical framing members of a gate shall be smooth, and shall not include
protrusions other than gate hardware to a maximum of 1/2” (0.50 in. /12.7 mm). All gates shall be designed
with sufficient lateral stability to assure that the gate will enter a receiver guide.
7. Class IV vehicular vertical pivot gates shall be designed, constructed and installed in accordance with
security related parameters specific to the application in question.
8. Controls intended for user activation must be located at least six feet (6’) away from any moving part of
the gate and where the user is prevented from reaching over, under, around or through the gate to operate
the controls. Exception: Emergency access controls only accessible by authorized personnel (e.g. fire, police,
EMS) may be placed at any location in the line-of-sight of the gate.
9. A minimum of four (4) WARNING SIGNS shall be installed, two on each side of the gate where easily
visible when the gate is open or closed.
10. A vehicular gate operator or vehicular drop arm operator shall have provisions for, or be supplied with, at
least two (2) independent monitored entrapment protection means as specified in UL 325 Table 31.1 for
each entrapment zone. At installation, both entrapment protection devices must be installed.
Vertical Pivot Gate Systems
Operator Entrapment Protection Types
Type A Inherent entrapment protection system (built into the control board)
Type B1 Non-contact sensors such as photoelectric sensor (Photo Beam)
Type B2 Contact sensors such as edge sensors
Note The same type of device shall not be utilized for both entrapment protection means. Use of a
single device to cover both the opening and closing directions is in accordance with the requirement;
however, a single device is not required to cover both directions. A combination of one Type B1 for one
direction and one Type B2 for the other direction is the equivalent of one device for the purpose of
complying with the requirements of either entrapment protection means. This operator is provided with
Type A built into the control board. The installer is required to install additional entrapment protection
devices in each entrapment zone.
1.800.944.4283 AutoGate Technical Support MAY 2017
4
END USER / INSTALLER CHECK OFF LIST
IT IS RECOMMENDED THAT EACH ITEM ON THIS INSTALLATION CHECKOFF LIST
BE DISCUSSED WITH THE END USER.
____ FOUR WARNING SIGNS SECURELY INSTALLED, TWO ON EACH SIDE OF GATE VISABLE IN BOTH OPEN AND
CLOSED POSTION. (REQUIRED)
____ TWO MEANS OF ENTRAPMENT PROTECTION ARE INSTALLED TO REVERSE THE GATE IN THE CLOSING DIRECTION
(i.e. PHOTO BEAM, CONTACT SENSOR OR TYPE A CURRENT SENSING PER UL 325—6TH EDITION (REQUIRED)
____ OTHER ENTRAPMENT RISKS IN THE GATE TRAVEL AREA HAVE BEEN PROTECTED PER ASTM F-2200
(i.e. SCREENING, FENCING, ETC.) ( REQUIRED)
____ CUSTOMER ADVISED THAT GATE IS FOR VEHICULAR TRAFFIC ONLY. (REQUIRED)
____ A SEPARATE PEDESTRIAN ENTRY AND/OR EXIT IS PROVIDED. (REQUIRED)
____ GATE GUARD/FENCED OFF AREA INSTALLED ON BACK SIDE OF OPERATOR. (REQUIRED)
____ KICK PLATE INSTALLED ON DOOR SIDE OF OPERATOR. (REQUIRED)
____ ALL ACCESS CONTROL DEVICES A MINIMUM OF SIX FOOT (6’) AWAY FROM THE MOVING GATE PANEL. (REQUIRED)
____ CLASS OF OPERATOR IS APPROVED FOR THE APPLICATION OF THE OPERATOR (CLASS 1,2,3,4) (REQUIRED)
____ CONTROLS INTENDED TO RESET GATE AFTER BEING OBSTRUCTED ARE INSTALLED IN LINE OF SIGHT (REQUIRED)
____ FIELD WIRING SECURED TO AVOID PINCHING DAMAGE.
____ CUSTOMER INSTRUCTED AND IS CLEAR ON PROPER USE OF GATE OPERATOR. (REQUIRED)
____ CUSTOMER INSTRUCTED ON PROPER USE OF ALL CONTROL DEVICES USED WITH OPERATOR.
____ SAFETY INSTRUCTIONS WERE REVIEWED AND LEFT WITH CUSTOMER. (REQUIRED)
____ DISCUSS THE POTENTIAL FOR A PREVENTATIVE SERVICE AND MAINTENANCE CONTRACT.
____ A PHOTO OF COMPLETED INSTALLATION TAKEN FROM FRONT AND BACK OF GATE & DATED.
____ CUSTOMER TRAINED ON MANUAL OPERATION OF THE GATE.
____ CUSTOMER ADVISED NOT TO DISCONNECT THE UL 325 ENTRAPMENT ALARM IN ANY WAY
____ ALL ENTRAPMENT PROTECTION MEANS HAVE BEEN TESTED AND VERIFIED FOR PROPER OPERATION
THIS GATE OPERATOR IS INSTALLED FOR USE AS A CLASS ______ INSTALLATION.
Operator Class Designation
CLASS I - RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in garages or
parking areas associated with a residence of one to four single families.
CLASS II COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for
use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store
or other buildings accessible by or servicing the general public.
CLASS III INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR – A vehicular gate operator (or system) intended for use
in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the
general public.
CLASS IV - RESTRICTED ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a
guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general
public, in which unauthorized access is prevented via supervision by security personnel.
IT IS RECOMMENDED THAT END USER & INSTALLER
MUST RETAIN A COPY OF THIS CHECK OFF LIST FOR THEIR RECORDS
1.800.944.4283 AutoGate Technical Support MAY 2017
5
Table of Contents
Safety Information 2-3
Check Off List for Installer and End User 4
Table of Contents 5
Warning Instructions 6
Safety Instructions for Primary & Secondary Entrapment Protection 7
Recommended Secondary Entrapment Devices 7
Safety Instructions for Installers & Owners 8
Orientation 9-11
Preparations Prior to Installation 12-14
Installation 15-17
DC & AC Power Connecting, Operator Testing 18-21
Accessory Components 22-23
Troubleshooting & Checking Control Board 24-25
Electrical Quick Check Guide 26
Control Board Layout 27
Maintenance 28-30
Drawings 31-42
1.800.944.4283 AutoGate Technical Support MAY 2017
6
WARNING!
TO REDUCE THE RISK OF INJURY OR DEATH, READ AND FOLLOW ALL INSTRUCTIONS!
REDUCE RISK
1. Follow the safety standards of the Occupational Safety and Health Administration (OSHA), as well as any
applicable Federal, State, Local Project Specification and Industry Standards or Procedures.
2. Only experienced personnel are to install, operate and maintain the equipment. Serious injury or
equipment damage can occur if installed or operated by untrained personnel. Operators of the equipment
must follow the specific instructions and safety precautions located in this manual.
3. At NO time should the Gate Panel/Drop Arm be modified in any way.
4. Do not add any additional weight to the Gate Panel/Drop Arm without contacting AutoGate first. This can
affect the balancing and operation of the system.
5. Always keep people and objects away from all moving parts and entrapment/pinch points of the system.
NO PERSON OR OBJECT SHOULD CROSS THE PATH OF THE MOVING GATE.
6. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an
object activates the non-contact sensors or contact sensor. Sensitivity is adjusted at the “OC” or “CC” pro-
gramming function. Failure to adjust and reset the gate operator properly can increase the risk of injury
or death.
7. Use the belt tension lever release only when the gate panel/drop arm is not moving and powdered down.
8. Install the vehicular gate operator only when the operator is appropriate for the construction of the gate
panel/drop arm and the usage class of the gate.
9. The system is intended for only gates used for vehicles. Pedestrians MUST be supplied with a sepa-
rate access opening. The pedestrian access opening shall be designed to promote pedestrian usage.
Locate the gate panel/drop arm such that persons will not come in contact with the vehicular gate panel/
drop arm during the entire path of travel of the vehicular gate panel/drop arm.
10. The gate must be installed in a location so that enough clearance is maintained between the gate and
adjacent structures when opening and closing to reduce the risk of entrapment.
11. Check the are area where the gate will be installed and operated for overhead wires, limbs, buildings,
signs or any other fixed objects that may interfere with the gate travel.
12. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the
gate panel/drop arm and where the user is prevented from reaching over, under, around or through the
gate panel/drop arm to operate the controls.
SAVE THESE INSTRUCTIONS
Automatic Gate Operators can produce high levels of force, therefore, it is very important that all gate
operator system installers and designers are fully aware of potential hazards that exist with an incorrectly
installed or designed system. The internal safety capabilities of a gate operator system are not enough to
reduce the risk of injury. The operator is only one part of a properly installed system which when combined
with all ASTM F2200 requirements and correctly installed approved entrapment devices will yield a
completed UL 325, 6th ed. and CSA 22.2 NO. 247-14 listed system that will not only provide convenience and
security, but will be safer with a minimal risk of injury. The following information contained in this manual
along with the installation checklist provided will make you aware of potential areas that are of a safety
concern. Disregarding any of the following may result in SERIOUS INJURY OR DEATH!
1.800.944.4283 AutoGate Technical Support MAY 2017
7
SAFETY INSTRUCTIONS REGARDING PRIMARY & SECONDARY
ENTRAPMENT PROTECTION
This unit is equipped with one (1) INTERNAL means of entrapment protection. (SEE UL 325 SECTION 30A)
Gate Operator shall provide one (1) INTERNAL (INHERENT) AND one (1) EXTERNAL entrapment feature.
INTERNAL:
(TYPE A) Inherent entrapment sensing systems operator will reverse direction when the inherent TYPE A
device senses an obstruction.
EXTERNAL:
(TYPE B1) – Provision for connection of a non-contact sensor (Photoelectric or equivalent)
(TYPE B2)— Provision for connection of a contact sensor (Edge devise or equivalent).
NOTE: Unit ships with S1-6 ON & S1-8 OFF. DO NOT change these settings (see page 12 for illustration).
PRIMARY PROTECTION- TYPE A INHERENT PROTECTION:
The unit will reverse direction when an obstruction is sensed while moving either direction. Sensitivity is
adjusted at the IRD1 on the control board while closing. If an obstruction is sensed by the primary inherent
sensor, the gate will reverse and open to the full open position. The gate will remain open until a close
command is received or will close by timer (if activated) after a new input is received. In order for the gate to
close by timer, a new input on the terminals J5-1-8 must be given. If an input is still present when the gate HAS
reached the full open position, this input will need to be renewed or removed and another input given before
the close timer will close the gate.
ENTRAPMENT ALARM:
Will activate upon the primary inherent sensor sensing a second obstruction before reaching a limit switch.
Once activated, the gate will remain at rest and an alarm will sound. The alarm can only be cleared by an input
applied to J5#4. The wiring used to reset the operator MUST be in the line of sight and MUST be an
“INTENDED” reset. Access control devices of any kind that require an intended activation may be
used for this reset. Devices that will cause an incidental reset should not be used, these include;
vehicle detectors, probes, timers, motion sensors, photo beams. Turning off the DC battery power
AND turning off the AC power at the GFCI service outlet will also reset the control board.
WARNING!
FAILURE TO COMPLY WITH THIS REQUIREMENT MAY RESULT
IN SERIOUS INJURY OR DEATH
APPROVED SECONDARY ENTRAPMENT DEVICES
PHOTO BEAMS
1)EMX INDUSTRIES MODEL#: IRB-325 TRANSMITTER / RECEIVER TYPE
2)ALLEN BRADLEY MODEL#: 60-2728 RETRO-REFLECTIVE TYPE
3)OMRON / MMTC MODEL#: E3K-R10K4-NR RETRO-REFLECTIVE TYPE
REVERSING EDGES (CONTACT EDGES)
MILLER EDGE MODEL— ME-120
1.800.944.4283 AutoGate Technical Support MAY 2017
8
WARNING!
TO REDUCE THE RISK OF INJURY OR DEATH, READ AND FOLLOW ALL INSTRUCTIONS!
SAFETY INSTRUCTIONS FOR INSTALLER AND END USER
Proper design is important in your system layout and installation. Entrapment devices must be used at all
available points where injury or property damage may occur. For protection from injury to persons, use
approved Entrapment devices across the driveway. Reversing Loops (Vehicle Detectors) should be installed
in front and behind the gate to provide a reverse signal or stop signal to the gate operator. All reversing
devices should be tested and inspected monthly. If a Reserving Loop or Loop detector malfunction, operator
should be disabled until repair can be made by an experienced service company.
In providing the service of “designer” or “installer” of the operator and gate system, you are responsible for
educating the END USER on proper and safe operation of the gate system. All precautions to eliminate
hazards MUST be taken before the system can be put into operation. All identified entrapment areas are
required to be protected against entrapment. Refer to ASTM F2200 for diagrams of common entrapment
areas.
Check the National, State & Local building and fire codes BEFORE installation
If you did not order a Reversing Edge (for along the bottom rail of your gate), or an Infra-Red Modulat-
ed Photocell (Reversing Beam), you will NOT be in compliance with March 2000 UL 325 Code, Rev 5.
Consult your dealer for additional information.
Pedestrians must use a separate entrance/exit and never the vehicular entrance/exit gate.
NEVER activate the gate from long distances where visibility of the gate cannot be seen. Anyone
operating the gate should always operate it in a safe manner.
NEVER allow children or anyone to play on or around the gate at any time.
DO NOT affix any adhesive material within 30 days of receiving the system.
DO NOT attach anything to the gate over four (4) pounds total weight or four (4) square feet without
consulting AutoGate for re-balancing instructions. The gate must remain balanced to ensure safe and
reliable operation.
The gate and operator are designed to work together. DO NOT attempt to install an unauthorized gate
without AutoGate’s prior authorization and instructions, doing so may VOID the operator warranty.
DO NOT ALLOW any access control devices to be mounted within 6 feet of the moving gate or in such a
way that someone could reach their hand or arm through the gate to activate it.
WARNING!
THE GATE OPERATOR IS DESIGNED AND FACTORY BALANCED FOR THE SPECIFIC GATE
IT WAS SUPPLIED WITH.
DO NOT MODIFY THE GATE IN ANY WAY OR ADD SIGNS WEIGHING MORE THAN 4 LBS TOTAL
OR FOUR (4’) SQUARE FT.
FAILURE TO COMPLY WITH THIS REQUIREMENT WILL VOID THE WARRANTY AND MAY RESULT
IN SERIOUS INJURY OR DEATH.
1.800.944.4283 AutoGate Technical Support MAY 2017
9
ORIENTATION
The AutoGate Vertical Pivot Gate (VPG) in this manual you will see it referred to as “system” .The VPG has
many features that make it effective, reliable, and easy to use, and some of these important features are
summarized in the table below. Note that not all systems are identical as width, gate panel implementation,
finish, accessories such as lights, and other accessory component options vary order to order. Below are
some key features to the System.
GLOSSARY & TERMS
Figure 1.1 through 1.3 will orient you to the basic components of the system. Most of the terms are self
explanatory; however, the following will help you understand certain components and terms.
Operator - A mechanical device used to open and close (raise and lower) a gate panel/drop arm system.
False Panel - Parallel to operator enclosure is the False Panel. It is permanently attached to the operator
and is comprised of two (2”) inch steel tubing and sheet metal. Its purpose is to protect pedestrian,
technician, and system users from being in the area of the pivoting gate panel/drop arm.
Hand (or handing) - The system comes in left hand or right hand configurations. This refers to the location
of the operator when viewed from the secured side of the closed Gate. To illustrate “handing” see the figure
1.1 for an example of a Right Handed (RH) system.
Feature Explanation
All Electric Operation.
NO HYDRAULICS!
24 volt DC with input voltage of 120-volt (standard) or 240-volt single phase.
Built-in battery backup for continued operation during power outages. Can be
outfitted with solar charging for remote locations without AC power. No hydraulic
fluids (for environmentally sensitive areas). Batteries are not included, but are
Gate Panel Options Ranging from highly decorative pickets to a simple chain link or industrial anti-climb
panels for military or correctional facilities.
Opens Completely The VPG opens fully to 90°. Easily accommodates tall vehicles and equipment.
Duty Cycle: Continuous The operator is engineered and rated for continuous duty and is specifically
designed for constant use throughout the day.
Low Maintenance Requires only periodic lubrication and annual tension adjustment. Very low order
of service required compared to our competition.
1.800.944.4283 AutoGate Technical Support MAY 2017
10
Operator Orientation
All of the operators mechanical and electrical components are housed inside the operator (See Figure 1.2
through Figure 1.4). The operator is a lockable steel cabinet that mounts on a raised concrete pad. A
separate NEMA 4x electrical enclosure is also housed inside the operator. The electrical enclosure contains
the master control circuit board and the terminal blocks/wire management system. It may also house a variety
of optional electrical components and configuration custom to your specific order.
Figure 1.1 Operator (not depicting Drop Arm or optional gate panel)
Figure 1.2 Components Housed in the Operator (Picture may not depict exact items)
Operator Gate Arm
Operator Gate Arm
False Panel
Cabinet Doors
Throat—the area between the operator and the false panel.
AMP Meter &
Cycle Counter
NEMA 4x
Electrical
Enclosure
Battery Shelf
GFCI Service
Outlet
(120 VAC, 15A
Footpads
Extension Springs
Transportation/Maintenance (T/M) safety
pin (shown in Drop Arm closed position)
Drive Pullies
(“Bullwheels” )
Electrical enclo-
sure is hiding the
2nd Bullwheel
Slide Assembly
Pivot Shaft
Linkage Arm
Drive Motor
1.800.944.4283 AutoGate Technical Support MAY 2017
11
Electrical Enclosure
The control board is configured to receive input commands from nearly any type of access control device
such as a card reader, keypad, push button panel, vehicular loop detector, over-speed detector, or even a
PLC. In short, the control board accepts dry contact inputs to provide the necessary open, close, or reversing
commands to the board. The control board also has a built in battery charging system to maintain proper
back-up battery voltage for hundreds of cycles in the event of a power outage.
The system can also be configured to operate: 1, 2 or 3 color traffic lights, audible alarm devices, external
emergency shut-off switch, output to an external source to indicate gate open/closed, and several other
configurations including LED warning lights on the Gate Panel/Drop Arm.
Pre-installed amp meter and cycle counters are a standard on all systems from AutoGate with the Liftmaster
Control Board..
AutoGate mounts the Liftmaster Control Board in a NEMA 4X Electrical enclosure box.
Figure 1.3 Electrical Enclosure (Inside)
Figure 1.4 Electrical Enclosure (Outside)
Loop Detector Sockets (Free Exit & Reversing)
Liftmaster
Control Board
Amp Meter
Cycle Counter
NEMA 4x
Enclosure
DC/Battery
Power Toggle Switch 1 AMP MAX 24 VDC
Accessory Power Strip
1.800.944.4283 AutoGate Technical Support MAY 2017
12
PREPARATIONS PRIOR TO INSTALLATION
T/M (Transportation & Maintenance) Safety Pin Warning!
When you receive your system, it has a safety device called a T/M Safety Pin installed (see Figures 2.1-2.3
below). T/M stands for Transportation and Maintenance because the pin must be installed during shipping,
installation, and whenever maintenance is being performed. Do not remove this pin until the instructions in
this manual direct you to do so!
FIGURE 2.1 Figure 2.2
Figure 2.3
SITE PREPARATION & PLANNING
Inspect the site and verify there are no underground utilities, overhead wires, or other obstructions that can
affect your installation and use. Keep routine foot traffic away from the system to reduce the chance of
pedestrians or site personnel contact with a moving system. A separate pedestrian gate or turnstile is highly
recommended to discourage the use of the system by anything other than vehicular traffic.
Determine if there are any accessory components to be installed with your system and necessary conduit
used for traffic lights, in-ground loops, access control stations, etc. and factor them into your sire layout and
installation plan.
High voltage and control wiring must NOT be run in the same conduit.
Concrete Pads
Concrete pads are required to install the VP Operator & Yoke. Along with securing the operator to the entry /
exit point, the pad provides a fixed and adequate foundation to resist wind and maintain stability for many
years of operation. Prior to pouring the concrete for the operator pad ensure the soil is undisturbed or
compacted to local or governing standards. (See DWG. 102-P)
4’ X 7’ Operator Pad Options:
1. Full Pad, Minimum depth of 36" or below local frost line
2. 10"-12” thick pad with five (5) 12" dia. x 36" deep holes or below local frost line
Springs Are Under High Tension!CAUTION!!
T/M Pin viewed from inside the operator
T/M Pin viewed in
the operator throat
Area (Door Keys are
attached here for
shipping)
1.800.944.4283 AutoGate Technical Support MAY 2017
13
Vehicle Loop Installation and Performance
Ground vehicle sensing loops are very common to gate sites. They are used for the detection of vehicles
which then triggers the gate to do a specific action. Proper installation and placement is critical. If you
purchased Pre-formed Loops carefully follow the enclosed installation instructions and use the diagram
below for the proper placement of the ground loops. If you are constructing the loops on-site, be certain to
use D.O.T. approved materials and methods.
Test the function of the loops thoroughly by using vehicles once installed to verify correct operation.
Figure 2.4
1.800.944.4283 AutoGate Technical Support MAY 2017
14
PREPARATIONS PRIOR TO INSTALLATION
RECOMMENDED TOOLS AND EQUIPMENT
Lifting Strap Multi-Meter (DCV & AMPS)
Hammer & Level Hammer Drill, 1/2 & 5/8 Bits
Grease Gun, Lithium Grease Tape Measure
Screwdriver Sets (Flat & Phillips) ½” Drive Socket Set: 1/2”, 9/16”, 3/4”, 15/16”, 1-1/8”
Electrical Tape Open End Wrenches: 1/2”, 9/16”, 3/4”, 15/16”, 1-5/16”
Wire Cutters/Strippers Misc. Electrical Connectors
Chalk Line Batteries (2) 12 VDC Group 24 Deep cycle marine
NOTE: Refer to manufacturer’s instructions of Accessory Equipment for correct wire size and type.
RECEIVING & UNLOADING INSTRUCTIONS
Unloading & Unpacking - Gate weight per foot varies with gate style & height and are approximate. Operator
weighs1150 lbs., steel gates are 24 lbs. per foot and aluminum gates weigh 19 lbs. per foot.
1. Have adequate equipment ready to unload your Gate and Operator safely. Utilize a Liftgate service when
available from the LTL carrier.
2. Before removing your Gate and Operator from the truck, inspect it for any visible damage and make sure
the Gate Box was shipped upright. (DO NOT DROP EITHER GATE OR OPERATOR BOX). Photograph
and retain if damaged as well.
3. After uncrating your Operator, locate and remove the door lock keys attached to the Transport/
Maintenance (T/M) Safety Pin. DO NOT REMOVE T/M PIN. ONLY REMOVE HAIR PIN RETAINER TO
REMOVE THE KEYS THEN REPLACE HAIRPIN. (See Figure 2.3)
4. Any transmitter, antenna, or other ordered accessories will be boxed inside your operator cabinet.
5. Unpack gate panel crating very carefully.
1.800.944.4283 AutoGate Technical Support MAY 2017
15
INSTALLATION
Installing VP Gate and Operator
1. Position Gate on Operator Arm.
2. Use (1) SS 3/4”-10 x 4 1/2” (STEEL GATE) or (1) SS 3/4”-10 x 5” (ALUMINUM GATE) Bolt for the top
connection. Use (4) SS 1/2 x 1-1/2" Bolts for the bottom connection.
3. Insert the top bolt first and then the bottom four (4) bolts finger tight. Be certain gate is properly aligned
before tightening. Tighten bottom bolts first, then tighten top bolt.
4. Locate washers and Linkage Pivot Bolt (5/8" x 2-1/4") and insert through rod end fitting and tighten bolt into
the gate lug hole as shown below. You may have to push down on the gate to insert Linkage Bolt.
Lifting Gate & Operator
To lift Gate & Operator use a lifting strap. The strap should be secured around Operator Arm and T/M Safety
Pin or the top rail of the gate near the operator arm. See Figure 3.2 & 3.3
Figure 3.2 Figure 3.3
NOTE: It is recommended to attach Gate to Operator Arm before lifting (for better balance), but it is not mandatory. If
using a Forklift to position Operator only, lift from sides only! Do not try to lift gate and operator together from the side
Positioning Gate Panel/Drop Arm & Operator
Refer to the site drawing for your specific order as there may be details unique to the installation.
1. Place Gate & Operator Assembly on pad so the end of the Gate is centered over the Yoke pad or intended
yoke position for the site (for yoke styles mounted to posts, buildings, etc.). Allow a minimum three (3")
inches from edge of pad to bolt holes to prevent concrete damage
2. Position and align Pad Yoke and center under gate.
3. Secure Operator with (1) 5/8" dia. Wedge Bolt in rear; check alignment on pad as well as gate panel/Drop
Arm alignment before installing remaining anchor bolts.
4. Install remaining four (4) 5 1/2” x 5/8" dia. Concrete Anchor Bolts provided, (level Gate Panel/Drop Arm
and Operator on pad, if necessary).
5. Secure Yoke with four (4) 1/2” dia. Anchor bolts (provided). If installing a Ground Yoke, allow a minimum
space of two (2") inches between bottom of Gate and Yoke.
Figure 3.1
Figure 3.1
1.800.944.4283 AutoGate Technical Support MAY 2017
16
Installing Other Components
Cable Wind Bracing
Masted Wind Bracing
1.800.944.4283 AutoGate Technical Support MAY 2017
17
KICK PANEL: Attach the Kick Panel to the door side
of the operator using the three (3) # 12 x 3/4 TEK
screws. See GREEN example kick Plate below.
Installing Other Components
GATE GUARD
NOTE: The area behind the operator is an entrapment zone.
The installer must prevent or protect pedestrian access to
this area by at least one or more of the following:
Install factory supplied Gate Guard
Site installed fencing
Utilize Recommended Entrapment Protection Devices
Entrapment Zones (RED shaded areas)
Fencing Gate in closed position Fencing
Fencing as an option
to restrict pedestrian
access in this area.
Opening Entrapment Zones
Gate in “OPEN” position below (shaded area)
requires installer to install one (1) of the fol-
lowing: Fencing, installation of provided gate
guard, or entrapment protection devices.
Closing Entrapment Zone
Below illustrates the minimum known entrapment zone
when gate is closing. Installation of an approved B1
non-contact sensor (Photo Beam) is shown in blue
including beam path. Additionally, installation of an
approved B2 contact sensor is shown in bright green.
WARNING!
THIS PAGE ILLISTRATES THE MINIMUM KNOWN
ENTRAPMENT ZONES. ANY OTHER ENTRAPMENT
ZONES MUST BE MITIGATED BY THE INSTALLER
IN ACCORDANCE WITH UL 325 & ASTM F2200 TO
REDUCE THE RISK OF PROPERTY DAMAGE, INJURY
OR DEATH. THE INSTALLER MUST REDUCE PUBLIC
EXPOSURE TO POTENTIAL HAZARDS.
1.800.944.4283 AutoGate Technical Support MAY 2017
18
Initial Power Connection & Operator Testing
1. Connecting Batteries - Required
A. Install two (2) 12 VDC Batteries (not provided) on the battery shelf. AutoGate recommends Group 24,
100 Amp hour deep cycle marine batteries for extended battery back up. At a minimum use seven (7) AH
batteries for battery back up. See drawing below for proper battery and jumper hook up. BATTERIES
MUST REST IN A LEVEL POSTION ON THE BATTERY TRAY TO AVOID ACID LEAKING FROM
BATTERIES.
B. Install Jumper Wire (provided) from Battery #1 - POSITIVE to Battery #2 - NEGATIVE (See Below).
C. Locate RED and BLACK Power Wires and connect:
NOTE: Battery back up duration will depend on the size of batteries, number of accessories and open/close
cycles while being powered by the batteries.
2. Temporarily remove any wires in the main circuit board J5 Strip, Terminal #5 (rev./safety) to disable any
Reversing devices not installed from preventing the gate from closing.
3. With all personnel clear of any moving part or component of the system you will take the next steps to
cycle the gate up and down a few times to verify proper operation. Turn Main DC Power Switch “on”.
(Located under the Electrical Enclosure) Use the S3 manual open/close switch on the control board.
4. Verify basic operator system function
NOTE: The gate should activate and open in approximately 10-12 seconds. In DC only operation the
cycle time could vary. If your gate does not lift properly, refer to "Troubleshooting Tips" pages 22—23.
12 VDC Battery
12 VDC Battery
Black Lead
Red Lead
BLACK TO BATT. #1 - NEGATIVE
RED TO BATT. #2 - POSITIVE
CAUTION: At this point you have no external safety devices
connected to your operator. Open with care!!
!
Use the MANUAL Open-Close
switch to test your operator.
Jumper
1.800.944.4283 AutoGate Technical Support MAY 2017
19
AC POWER CONNECTION
Connecting AC Power
1. Turn Off DC power.
2. Wire incoming AC power to the 4 x 4 Box provided and turn on the breaker from your AC Source.
3. Turn AC Power Switch on at the 4 x 4 Box.
NOTE: The A/C Power must be connected by a qualified, licensed Electrician, according to the National Electric
Code, and all State and Local codes. Refer to electrical block diagram for additional information.
WARNING!
TO REDUCE THE RISK OF ELECTRICAL SHOCK, THIS EQUIPMENT HAS A GFCI TYPE PLUG
THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING TYPE
OUTLET. IF THE PLUG DOES NOT FIT IN THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN
TO INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
Operator Main AC Power Switch
(pre-wired to outlet)
120 AC (Black) (BRASS terminal)
Neutral (White) (SILVER terminal)
Green (Ground)
ON
A/C ELECTRICAL SUPPLY
MINIMAL REQUIREMENTS:
120 VAC, 15AMP CIRCUIT
FOR CLASS 1 APPLICATIONS YOU
MAY NOT EXCEED 15 AMPS
WARNING!
ADDITIONAL 120 VAC SURGE PROTECTION IS RECOMMENDED BUT NOT REQUIRED.
SURGE UNIT MUST BE GROUNDED TO A TRUE EARTH GROUND.
AC OUTLETS ARE HOT AT ALL TIMES. OUTLETS ARE FOR SERVICE USE ONLY.
OPERATOR MUST BE GROUNDED TO TRUE EARTH GROUND LUG LOCATED ON FRAME
Pre-Mounted 120 VAC Electrical Outlet & AC Power Switch Electrical Connection
1.800.944.4283 AutoGate Technical Support MAY 2017
20
CONTROL BOARD
The VP gate has many features and options. Most are controlled by an electronic circuit board inside the
Control Box. The circuit board is factory set and should not be altered in any way or the Warranty may be
voided. If an adjustment has to be made, consult your Control Board Instructions for details. If you need any
further assistance, please contact your local AutoGate Dealer or call AutoGate at 1-800-944-4283.
Timers and Mode Selections (S1) SEE DIAGRAM BELOW
Full Speed Run Timer Switch Pack S1 (1-5) Switches one (1) through five (5) are FACTORY PRESET.
DO NOT CHANGE!
Mode Selections – Switch Pack S1 (6-8). SEE DIAGRAM ABOVE
SWITCH 6 – “On”. This is set for the UL 325 Alarm. (DO NOT CHANGE!).
SWITCH 7 - FACTORY PRESET. (DO NOT CHANGE!).
SWITCH 8 – “Off” Not used on this system.
S2
Timers & Mode Selections – Switch Pack S2 (1-8). SEE DIAGRAM ABOVE
SWITCHES 1-5 on S2 are for the closing timer delay. Default is S2-3 “ON” to provide a eight (8) second delay
if activated. If S2-7 is on, the gate will auto close by timer.
SWITCH 6 Sets auxiliary. Open input terminal #4 at J5 to be pulse open-pulse close (Default is On).
SWITCH 7 AUTO CLOSE TIMER Default is ON. When on, use S2 1-5 to set close time delay. When
close timer is selected, you MUST install vehicle and pedestrian detection devices.
SWITCH 8 AUTO OPEN ON POWER FAILURE When switch eight (8) is in the ON position, the operator
will automatically open the gate approximately 15 seconds after the loss of power. Once
power is restored, the operator will resume normal operation. Factory setting is “OFF” allowing
the operator to function normally until the battery power has diminished. Once A/C has been
restored, the operator will function normally.
NOTE: If batteries were completely discharged, remove from operator and recharge with a commercial grade
battery charger.
1-5 Fast Run Timer 6-8 Mode Selection
1 2 4 8 16 (Seconds)
1 2 3 4 5 6 7 8
ON
OFF
S1
2 4 8 16 32 (Seconds)
1 2 3 4 5 6 7 8
1-5 Closing Time Delay 6-8 Read Below
ON
OFF
1.800.944.4283 AutoGate Technical Support MAY 2017
21
Instant Reverse Device (IRD) - The Internal Entrapment Protection Device
The Instant Reverse Device is an internal circuit that continuously monitors the motors current for increase
draw. This is factory preset for your specific gate size. To test for proper operation, position yourself approxi-
mately 2/3 of the way across the driveway. With the gate descending, carefully catch the gate to simulate an
obstruction and it should stop and reverse within two (2) seconds. If the gate does not reverse, call the
factory for technical assistance. If obstructed while closing, the gate will stop and reverse to the open
position, time out (using the time delay set at S2 switches 1-5) and then close. If gate is opening when
obstructed, the gate will stop its open travel. If inputs are present, gate will remain stopped. If no inputs are
present or existing are cleared, the gate will time out and close.
Primary—Secondary Wiring (Two systems designed to work together as an entry or exit point)
In a primary/secondary configuration, either unit can be the primary. Choose one unit to be the master and
then direct all control wiring to it (also install vehicle detector and receivers in it). At the PRIMARY any input
(at J5) with control (detectors, receivers, keypads, timers, etc.) wires to it must also be run to the same termi-
nals of the secondary system. Along with these control wires, both operators MUST share a common ground
connection from chassis to chassis (or from common to common , i.e. master gate J5 terminal #12 to second-
ary unit J5 terminal #12).
EXAMPLE: If only open and reversing are used at primary then three wires will run between gates.
If it is required that if one gate senses an obstruction, the other reverses also, then three (3) additional wires
must be run between the primary J3 and secondary J3 as shown below. These connections are for
transmitting IRD (obstruction signals) between both units. This will allow the primary or secondary to inform
the other that a closing obstruction has occurred and for it to also reverse and open. SET switches on S2, 1-8
the same on both gates.
PRIMARY - J3
SECONDARY - J3
THE CONNECTIONS TO THE LEFT MUST
BE DONE IN ORDER FOR GATE IRD'S TO
WORK CORRECTLY. TERMINAL 1 OF PRI-
MARY MUST GO TO TERMINAL 4 OF SEC-
ONDARY. TERMINAL 1 OF SECONDARY
MUST GO TO TERMINAL 4 OF PRIMARY.
TERMINAL 2 OF PRIMARY WILL GO TO
TERMINAL 2 OF SECONDARY.
IRD - OBSTRUCTION
SIGNAL CONNECTIONS
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
REVERSING
OPEN
COMMON
PRIMARY – J5
SECONDARY—J5
WARNING!
INHERENT REVERSE DEVICE (IRD) SHOULD BE TESTED PERIODICALY TO INSURE PROPER OPERATION.
1.800.944.4283 AutoGate Technical Support MAY 2017
22
ACCESSORY COMPONENTS
If your system came with accessory or optional components that require installation or setup, you must
review this section for Operator Wiring & Testing and instructions provided by the component manufacturer.
In general, those instructions provide guidance needed for installing and using these accessory components.
The following table lists the accessory components that may have been provided with your system.
Component or System Comments
Note: Certain components should be considered mandatory on all systems. These are noted below and
should be procured, installed, and tested before the system is commissioned and used by the owner.
Vehicle Loops & Loop Detectors
These are required to restrict or limit gate operation under
certain vehicle detection or in conjunction with access control
station vehicle presence detection. A socket for the loop
detector electronic control modules are pre-installed in the
electrical enclosure. Installer must: fabricate and install loops
in the roadway, install the control module (detector), complete
the hookup, and programs/adjust detector sensitivity for good
interaction of the loops and the gate system.
Infrared Photo Electric Sensors
Used to stop and reverse the Gate Panel/Drop Arm when
closing. If an object passes through or blocks the beam, the
Drop Arm will remain open while the beam is blocked.
Gate Edge Sensors
Edges are to cover the entire bottom edge of the gate and are
used to stop and reverse the Gate Panel in the intended
direction of travel.
Traffic Signal Lights—1 lens, 2 lens, or 3
lens (Ex: Red, Yellow, Green)
Used to warn of the barrier systems presence and operation.
AutoGate recommends an Red LED lens at all times, except
when the Gate Panel/Drop Arm is in its fully open position, in
which case we recommend a Yellow (amber) flashing lens.
Warning Signs, Reflective Tape, Warning
Lights
Drivers should be alerted to the presence of a high-stopping
power barrier system, and that striking the barrier will cause
injury or death. Speed limits should also be posted. Contact
AutoGate for specific Warning Signs, Reflective Tape, and
Warning Lights that can be affixed to the Drop Arm.
1.800.944.4283 AutoGate Technical Support MAY 2017
23
OPTIONAL ACCESSORY INSTALLATION INSTRUCTIONS
CAUTION! Failure to completely install any Reversing Devices may cause your gate to default Open. (Ex.: Hooking
up your Loop Wires to the Socket Base while not having the Detector plugged in, or having your IFR Receiver hooked
up and not the IFR Transmitter).
A. Reversing / Free Exit Loops and Detectors:
1. Locate your “Homerun” lead-in Loop wires and connect the Free Exit Loop to Socket Base
connections #7 and #8 (Free Exit Devise).
2. Locate you “Homerun” lead-in Loop wires and connect the Reversing Loop(s) to Socket Base
connections #7 and #8. You can wire two (2) Reversing Loops to one (1) Socket Base (Reversing
Devise). Check the Loop instructions for proper phasing.
3. Plug in Loop Detector in the pre-wired socket base(s).
B. Photoelectric Sensors:
1. Verify voltage compatibility, 24v DC is required.
2. Connect signal wire N.O. (normally open) to terminal #5 on your control board.
3. Connect the ground wire to terminal 9, 10, 11, or 12 (commons).
4. Connect the power wires to the terminal strip located inside the control box.
C. Contact Sensor Edge:
1. Connect signal wire N.O. (normally open) to terminal #5 on your control board.
2. Connect the ground wire to terminal 9, 10, 11, or 12 (commons).
3. Be certain all wires are secured to prevent damage to the gate during operation.
D. Vehicle Sensor Probe (Car-Sense 101):
1. Locate the Car-Sense 101 Vehicle Sensing Probe either along the edge of the Exit Drive
2. Once installed, run the 2-conductor cable to Socket Base connections #6, 7 & 8 (Free Exit Device).
Refer to manufacturer’s instructions for proper wiring.
3. Connect the power wires to the terminal strip located inside the control box.
4. Connect signal wire to an open terminal – 1, 2, 3.
5. Connect the ground wire to terminal 9, 10, 11 or 12 (commons).
6. Plug in your Car Sense Detector in the pre-wired socket base.
E. Gate Auto Timer:
1. Install your timer in the electrical box.
2. Run a power wire from the time terminalA” the “Positive” on the control board, run a power wire from
the timer terminal “B” to the “Negative” on the control board.
3. Run a power wire from the time terminal 1” to “1”, “2”, or “3” on the control board, run a power wire
from the timer terminal “2” to “9”, “10”, “11” or “12” on the control board.
F. Keypads:
1. Refer to your Keypad Manufacturer’s Instructions for complete wiring.
2. Run the power wires to Terminal Strip main power (+ and -).
3. The N.O. & Common signal wire to open the gate need to be attached to the Circuit Board #’s 1, 2 or
3 (Open 9, 10, 11, or 12 (Common). (Refer to Manufacturer’s Instructions).
G. Card Readers:
1. Refer to your Card Reader Manufacturer’s Instructions for complete wiring.
2. Run the power wires to Terminal Strip main power (+ and -).
3. The N.O. & Common signal wires to open the gate need to be attached to the Circuit Board #’s 1, 2,
or 3 (Open) & 9, 10, 11, or 12 (Common). (Refer to Manufacturer’s Instructions.)
4. We recommend using a ground rod to minimize lightning damage.
1.800.944.4283 AutoGate Technical Support MAY 2017
24
TROUBLESHOOTING & CHECKING CONTROL BOARD
Checking Batteries & Charging
Note: When the batteries become weak the gate can begin to run erratically or stay open.
Turn off the AC power and put an Volt meter across the battery terminals to measure voltage.
Cycle gate for five (5) to ten (10) cycles while observing voltage and low battery indicator LED D12.
If LED 12 comes ON, the batteries are too weak to function properly. Correct voltage across the
batteries is a minimum of 23.5 to 25 VDC.
If LED D12 does light, gate will default open indicating LOW batteries. In this test or in a real power
loss, even if Switch 8 on S2 is off (refer to switch settings on pg. 20). Return of AC power will trickle
charge the batteries. You may have to re-charge the batteries as they may be too weak for the
board to re-charge quickly. If the batteries won’t charge, remove and LOAD test and replace if bad.
Correct charge voltage is 27.0—27.5 VDC with batteries not connected (adjustment is at R63).
Gate Will Not Close
Check for any active inputs on terminal inputs D15-D24, AC power loss, AC power switch is off or
weak batteries.
Check that batteries are connected properly. Is switch S3 in “ON” position (this is manual open
switch). Check if S2 switch number 8 is in “ON” position and if AC power is lost, See LED D14.
Check LED D12, if lit and AC power is off, then batteries need to be charged or replaced.
Gate Will Not Open
Check for AC power loss at D14 (check AC power switch) and that batteries are fully charged.
Check fuses and if inputs are wired correctly, test S3 manual open switch.
Gate Dead—No Operation
1. Make sure both DC Power Toggle Switch and A/C Power switch are on. If no LED lights are “lit” on
the board proceed to #2. If LED lights are “lit” verify HBEAT (D11) is flashing? If flashing proceed
and D12 BAT LOW LED is off proceed to #2 . If HBEAT (D11) is not flashing and other LED’s are
“lit” the control board is bad (contact AutoGate for replacement).
2. Check A/C indicator light on cabinet, is it on? Yes, go to step #3; No, check 3 amp fuse on battery
tray, if good, go to step #3, if bad replace and check again. If No A/C, source external power
problem back to fuse box.
3. Check F3 & F4 fuses on control board. If bad, replace. If they continue to blow the control board is
bad.
4. If D14 (AC) & D5 (BRAKE) are on, then gate has repeatedly sensed obstructions. Clear obstruction,
turn off AC and DC power. Now turn AC and DC power back on and test system.
5. If steps above do not restore operation contact AutoGate Tech Support at 1.800.944.4283.
WARNING!
WARNING: DISCONNECT BATTERIES AND AC POWER BEFORE SERVICING ANY MECHANICAL OR MOVING
COMPONENTS!
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, ONLY REPLACE WITH THE SAME TYPE AND RATING OF
FUSE.
1.800.944.4283 AutoGate Technical Support MAY 2017
25
IRD (D2) Led Is Flashing
MRT (Maximum Run Timer) has expired. Gate was unable to reach the closed limit switch. Check that
fast run timer is set to run as long as possible. (SW1 #’s 1-5 should all be on).
Fuse(s) Are Blown
F3 (15 AMP AC) AND/OR F4 (15 AMP DC) Check for shorts in wiring. If F3 AC fuse is blown, then
batteries may also be dead. If you continue to blow fuses and no apparent shortages are visible, you
most likely have a blown control board and it will need to be replaced.
Gate Closes Then Reverses
See IRD adjustments, also check for obstacles in gate travel, such as trees, sticks, etc. Check batteries
for voltage, if batteries are weak, it can cause the gate to not reach the close limit and re-open.
Charge Voltages
Charge voltage to batteries too low, adjust at R63. With batteries disconnected, set to 27.5.
Motor Doesn’t Stop
If gate closes and motor continues to run the limit switch may need adjustment or replacement.
IRD Obstruction Signal to Other Gate Note Working Correctly
Remove connector at J3, obstruct gate, LED D13 should go off for a few seconds. This indicates signal
was transmitted. Be sure gates have a common ground.
Manual Operation
The VP gate is easily operated manually in the event of total power or component failure.
1. Turn main power switches off (both A/C & D/C).
2. Release the belt tension lever located under the gear motor to remove the belt tension.
3. Position yourself in front of operator and lift up on Linkage Arm at the pivot point 1”-2”.
4. Walk out to end of gate and lift gate to the open position.
5. Place the T/M pin through the bracket holes to prevent the gate from lowering.
6. Secure the belt tension lever in the locked position to re-apply tension to the belts.
NOTE:
It only takes 16 - 30 lb. of force to open gate. If more is required, contact your dealer or
AutoGate.
1.800.944.4283 AutoGate Technical Support MAY 2017
26
ELECTRICAL QUICK CHECK GUIDE
Follow the steps in this chart to see if you can restore service of your gate.
This is a visual check without the use of a voltmeter.
Start by opening the cabinet door to the operator.
Then open the electrical control box and look on the control board for the HBEAT LED,
located at the lower left corner of the control box.
HBEAT
LED on
Steady
HBEAT off-
Check
A/C PWR
LED
A/C
PWR LED
ON?
Check BATT
LO LED
Control Board is
defective
Replace Control
Board
Check A/C
Switch
Is
Switch On?
Is HBEAT
LED flashing
or ON
Steady?
O/On Steady
Flashing
NO
YES
YES
Batteries Low
or Bad
Check input LED’s on
top Right Side of
Control Board
Any input on Will hold
gate open
Recharge or Replace Batteries
Check Wiring and Charging Output
Gate will not close if BATT LO LED is on
Replace any blown fuse with same Sizing and Rating. If fuses are
goodCheck for good batteries and A/C from building circuit breaker.
If any fuse blows instantly at power onBad Circuit Board
REPLACE
ON
Turn On
A/C Switch
Is HBEAT LED
On or
Flashing?
Check Fuses
3 Amp on front of
Battery Tray
F3 Fuse on
Control Board
NO
NO
YES
On Steady
Flashing
1.800.944.4283 AutoGate Technical Support MAY 2017
27
1.800.944.4283 AutoGate Technical Support MAY 2017
28
MAINTENANCE
The basic electrical and mechanical systems require only minimum routine maintenance. The following items
should be checked and serviced periodically depending on amount of use. Each item below has supporting
illustrations and/or instructions in this manual. Contact AutoGate for any questions or issues. Maintenance is
important to any gate system and can affect safety, warranty, quality operation, and life-cycle of the system.
ITEM RECOMMENDED MAINTENANCE
Grease pivot points on Linkage Assembly
(“LUBRIPLATE ‘R’ LOW TEMP” Grease)
10,000 cycles or 6 months
Grease all bearings: two (2) Operator Arm, four (4) Bullwheel Shafts
10,000 cycles or 6 months
Grease Chain Tension Bolt and Lube Chain & lightly coat springs 10,000 cycles or 6 months
Check belts for wear and tightness.
(Belt flex between motor and Intermediate sheaves is 1/4” deflection &
between intermediate and final drive sheaves should be tightened to
minimum deflection). Belt(s) loose or worn require replacement.
Every 6 months
Charge voltage for batteries should be 27.5 VDC with batteries disconnected
check at battery terminal on control board (set at R63).
Every 6 months
Check battery water level, use distilled water only (Not required on
maintenance-free)
Every 6 months
Clean snow/ice off of gate (Balance correctly, gate will temporarily tolerate an
additional 10 lb. of wt.)
As needed
Clean lenses on Photocells or Reflectors
As needed
Lubricate (Graphite Oil) all lock cylinders and mechanisms
Every 6 months
Check and verify proper operation of all External entrapment protection
devices. See page 23 and the external entrapment protection device(s) manu-
factures instructions.
Every month
Check and verify proper operation of the Internal entrapment protection
reversing feature (see page 21, IRD—Instant Reversing Device).
Every month
Check gate balance (see page 30) Four months after install, they annually
1.800.944.4283 AutoGate Technical Support MAY 2017
29
SPRING CHANGING INSTRUCTIONS
ONLY AUTHORIZED PERSONNEL SHOULD PERFORM SPRING CHANGES
Step 1) For ease of access, remove the door and end
panel nearest the gate.
Step 2) Disable the photo eye if equipped.
Step 3) Remove any upper “T” bolts completely
Step 4) Loosen the top adjusting nut of the slide assem-
bly. Thread the nut up to within four (4”) inches of the top
of slide mechanism.
Step 5) You will now raise the gate. (DO NOT release
the disengage lever!) Initiate the gate to open, immediate-
ly move to the gate and help raise it open, once the slide
moves up, hold on the bottom rail of the gate until fully
open. The gate may bounce slightly, there will be a loud
bang but no damage will occur.
Step 6) Turn Off AC & DC Power before gate “times out”
and tries to close. Insert T/M Pin.
Step 7) Using a 1 5/16 wrench, loosen and remove the
chain tension bolt with the damaged spring.
Step 8) Replace damaged spring
Step 9) Replace chain tension bolt. NOTE: Grease fitting
must point up! Tighten bottom nut. NOTE: Chain MUST
remain level and not twisted once tightened.
Step 10) Remove T/M pin and restore A/C & D/C power.
Step 11) Lowering the gate. Initiate the gate to close and
at the same time, assist the gate down by pulling on the
bottom rail of the gate. The slide will move down and
another loud bang as the gate is lowered.
Step 12) Turn off both A/C and D/C power.
Step 13) Thread the slide nut back down to the slide as-
sembly and tighten.
Step 14) Replace the T-Bolts to their original location and
tighten.
Step 15) Restore A/C and D/C power and hook photo eye
back up.
Step 16) Cycle gate.
Step 17) Spray all springs with a chain lube to prevent
corrosion.
RECOMMENDED: Always check and adjust the balance
after any spring change. Refer to balancing instructions at
www.AutoGate.com or the instructions on Page 30.
TOOLS REQUIRED: 5/16” (Nut Driver), 1/2”, 1 1/8”, 1 5/16” Open End Wrenches
1.800.944.4283 AutoGate Technical Support MAY 2017
30
QUICK REFERENCE GUIDE
Touch-Up Paint
For scratches and following minor repairs use Rustoleum® Painters Touch 2x Ultra Cover to match the
AutoGate Standard Colors. All colors Gloss Black, Dark Gray, Kona Brown, Hunter Green, & White.
Balancing a Gate
Recommended four (4) months after installation, then annually. It is recommended to check the balance
of the Operator. It is mandatory to re-check the balance if you change a spring(s). You can monitor it on
the amp meter installed on the control box door. It is recommended to follow the instructions below for
accurate balancing numbers using a commercial grade AMP meter.
Remove the wire nut on the RED motor lead and hook up one Amp Meter lead to the RED wire and the
other Amp Meter lead to the ORANGE wire. Cycle the gate up and down and record the highest amp
reading in both directions (reading should be in the 2.0 to 6.0 range). The highest reading for both the up
and down cycles should be very close to the same. If not, you will have to adjust the SLIDE ASSEMBLY.
Loosen the 1 1/8” nuts on either side of the Slide Assy. Angle on the Threaded Rod. If the gate Amps are
too high in the OPEN mode, move the Slide Assy. UP to help it OPEN. (This is the most common
adjustment Made). If the gate is flying open and struggling to close, move the Slide Assembly DOWN.
Only adjust the Slide Assembly 1/4” (3 to 4 turns) at a time when adjusting. After each adjustment, check
your amp readings.
When you have the gate back in balance (within a half amp (.5) is minimal), tighten both nuts on Slide
Assembly threaded rod.
Control Board Replacement
Turn ALL power off (AC & DC) to the board.
Remove (slide off) J2 “Open & Close” Limit Switch Terminal strip.
Remove (slide off) Accessories 1 through 12 Terminal strip.
Carefully remove the wires for the 24 VDC Acc. Power, Battery Power, AC Power & Motor wires.
Take the board off the Standoffs and remove the two (2) mounting bolts and replace with your NEW
circuit board and put all wires and connections back in the same place.
Double check the D.I.P. switch settings to be sure they are the same as your original board.
1.800.944.4283 AutoGate Technical Support MAY 2017
31
1.800.944.4283 AutoGate Technical Support MAY 2017
32
1.800.944.4283 AutoGate Technical Support MAY 2017
33
1.800.944.4283 AutoGate Technical Support MAY 2017
34
1.800.944.4283 AutoGate Technical Support MAY 2017
35
1.800.944.4283 AutoGate Technical Support MAY 2017
36
1.800.944.4283 AutoGate Technical Support MAY 2017
37
1.800.944.4283 AutoGate Technical Support MAY 2017
38
1.800.944.4283 AutoGate Technical Support MAY 2017
39
1.800.944.4283 AutoGate Technical Support MAY 2017
40
1.800.944.4283 AutoGate Technical Support MAY 2017
41
1.800.944.4283 AutoGate Technical Support MAY 2017
42