KANDIYOHI COUNTY
POLE BUILDING REQUIREMENTS 7/6/21
The following information must be submitted to the building department before a building permit can be processed
and approved.
Structures used for commercial purposes require professional design by a licensed Architect and Structural Engineer.
Structures used as a Single Family Dwelling require the building plans be designed by a licensed Structural Engineer.
If the building is for agricultural use (livestock, produce or farm implement storage), contact the zoning department for
a land use permit.
1. P
ermit Application Form
2. Survey or Site Pla
n
3. B
uilding Pl
ans
4. Roof Truss Specifications
5. S
eptic Compliance (if applicable)
6. Miscellaneous as required
A
more detailed description of items 1–5 is listed below.
A
fter a preliminary review, additional information may be required. Allow a minimum of ten (10) working days for
processing.
1. B
uilding Permit Application: Complete a Building Permit application form. Application forms a
nd
handout
s are also available on-line at www.kcmn.us
2. S
ite Plan: Complete the Site Plan form providing an updated diagram of the property. The type of
information required and details to be included regarding the construction site are listed at the top of the
form. An example of a site drawing is provided for reference. A registered survey may be required.
3. B
uilding Plans:
A. Section Drawing: Provide (side cutaway drawing) showing the footing width, thickness, and depth
below grade, anti-wind lift for the pole, pole dimensions, wall construction, wind bracing, roof framing,
purlin spacing and grade of lumber, truss bracing and connection, and roof covering material.
B. Floor Plan: Provide floor plans showing length and width of the building, post spacing, window and
door locations, header sizes, interior walls and plumbing fixtures, heating equipment to be used if any.
W
rite on the floor plan a written description of the use of all areas of the building such as cold storage,
heated space, bathroom, car storage area, shop area, etc. Overhead doors must be 90 MPH wind rated. This
includes being tested and being in compliance with ANSI/DASMA 108.
C. Elevation Drawings: Provide drawings of the front, rear and sides of the finished building. Include
side wall height and the height to the peak from grade.
4. R
oof Truss Specifications: Provide a copy of the manufacturer’s roof truss design (signed by a licens
ed
eng
ineer showing the truss span, spacing, design snow load, dead loads, required bracing, spacing and grade of
the lumber used for the roof purlins). Check with the local Building Official before ordering trusses to determine